112 research outputs found

    Quantification de la perfusion hépatique dans les images échographiques de contraste

    Get PDF
    Cet article présente une nouvelle technique de quantification automatique de la perfusion hépatique dans les images échographiques de contraste. Elle exploite les caractéristiques des séquences pour construire une nouvelle méthode de diffusion anisotrope robuste permettant de s'affranchir des problèmes de seuillage et d'obtenir un traitement qui s'adapte en tout point à l'information contenue dans l'image. Cette approche est ensuite couplée avec une classification floue non exclusive pour segmenter les lésions

    Comparison of intima-media thickness and ophthalmic artery resistance index for assessing subclinical atherosclerosis in HIV-1-infected patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Human immunodeficiency virus (HIV) infection and antiretroviral treatment are associated with metabolic and cardiovascular complications that potentially increase the risk of atherosclerosis and cardiovascular disease in this population. Measurement of arterial wall thickness has been used as a surrogate of extent, severity and progression of atherosclerosis. A cross-sectional cohort study was performed to compare the validity of two non-invasive arterial measures: carotid intima-media thickness (IMT), a parameter of atherosclerosis, and ophthalmic artery resistance index (OARI), an index of occlusive carotid artery disease.</p> <p>Methods</p> <p>A total of 95 patients receiving highly active antiretroviral therapy (HAART) for more than 12 months were consecutively enrolled. IMT and OARI were measured by 7.5 MHz linear probe.</p> <p>Results</p> <p>There was a significant linear increase in IMT and OARI values as the grade of cardiovascular risk (0.70 and 0.69 for very low risk, 0.86 and 0.72 for low risk and 0.98 and 0.74 for medium/high risk, p < 0.001). A IMT > 0.83 and an OARI > 0.72 were the most discriminatory values for predicting a cardiovascular risk ≥ 10% (sensibility 89.6% and 75.8%; sensitivity 70.5% and 68.4%; p < 0.001).</p> <p>Conclusions</p> <p>Our data indicate that OARI may have a potential as a new precocious marker of subclinical atherosclerosis in HIV-1-infected patients.</p

    The Effect of Contrast Medium SonoVue® on the Electric Charge Density of Blood Cells

    Get PDF
    The effect of contrast medium SonoVue® on the electric charge density of blood cells (erythrocytes and thrombocytes) was measured using a microelectrophoretic method. We examined the effect of adsorbed H+ and OH− ions on the surface charge of erythrocytes or thrombocytes. Surface charge density values were determined from electrophoretic mobility measurements of blood cells performed at various pH levels. The interaction between solution ions and the erythrocyte’s or thrombocyte’s surface was described by a four-component equilibrium model. The agreement between the experimental and theoretical charge variation curves of the erythrocytes and thrombocytes was good at pH 2–9. The deviation observed at a higher pH may be caused by disregarding interactions between the functional groups of blood cells

    Ultrasound-assessed perirenal fat is related to increased ophthalmic artery resistance index in HIV-1 patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The introduction of highly active antiretroviral therapy (HAART) has dramatically changed the prognosis of human immunodeficiency virus (HIV) infection, with a significant decline in morbidity and mortality.</p> <p>Changes in body fat distribution are a common finding in individuals with HIV infection being treated with antiretrovirals, and this condition (collectively termed lipodystrophy syndrome) is associated with depletion of subcutaneous fat, increased triglycerides and insulin resistance. Obesity, particularly visceral obesity, is associated with increased risk of cardiovascular disease. Therefore, estimating visceral fat distribution is important in identifying subjects at high risk for cardiovascular disease.</p> <p>The aim of our study was to evaluate whether perirenal fat thickness (PRFT), a parameter of central obesity, is related to ophthalmic artery resistance index (OARI), an index of occlusive carotid artery disease in HIV-1 infected patients.</p> <p>Methods</p> <p>We enrolled 88 consecutive HIV-1-infected patients receiving highly active antiretroviral therapy for more than 12 months, in a prospective cohort study. Echographically measured PRFT and OARI, as well as serum metabolic parameters, were evaluated. PRFT and OARI were measured by 3.75 MHz convex and 7.5 MHz linear probe, respectively.</p> <p>Results</p> <p>The means of PRFT and OARI in HIV-1-infected patients with visceral obesity was considerably higher than in patients without it (p < 0.0001 and p < 0.001, respectively). Using the average OARI as the dependent variable, total serum cholesterol level, HDL, triglycerides, glycemia, sex, blood pressure, age and PRFT were independent factors associated with OARI. A PRFT of 6.1 mm was the most discriminatory value for predicting an OARI > 0.74 (sensitivity 78.9%, specificity 82.8%).</p> <p>Conclusions</p> <p>Our data indicate that ultrasound assessment of PRFT may have potential as a marker of increased endothelial damage with specific involvement of the ocular vascular region in HIV-1-infected patients.</p

    Voiding urosonography with ultrasound contrast agents for the diagnosis of vesicoureteric reflux in children: I. Procedure

    Get PDF
    Voiding urosonography (VUS) encompasses examination of the urinary tract with intravesical administration of US contrast agent (UCA) for diagnosis of vesicoureteric reflux (VUR). The real breakthrough for US examination of VUR came with the availability of stabilized UCAs in the mid-1990s. This article presents a comprehensive review of various procedural aspects of VUS. Different US modalities are available for detecting the echogenic microbubbles: fundamental mode, colour Doppler US, harmonic imaging and dedicated contrast imaging with multiple display options. The reflux is graded (1 to 5) in a similar manner to the system used in voiding cystourethrography (VCUG). The most commonly used UCA for VUS, Levovist, is galactose-based and contains air-filled microbubbles. The recommended concentration is 300 mg/ml at a dose of 5–10%, or less than 5%, of the bladder filling volume when using fundamental or harmonic imaging modes, respectively. There are preliminary reports of VUS using a second-generation UCA, SonoVue. Here the UCA volume is less than 1% of the bladder filling volume. There is no specific contraindication to intravesical administration of UCA. The safety profile of intravesical Levovist is very high with no reports of side effects over a decade of use in VUS

    The Effect of Axial Length on the Thickness of Intraretinal Layers of the Macula.

    Get PDF
    PURPOSE: The aim of this study was to evaluate the effect of axial length (AL) on the thickness of intraretinal layers in the macula using optical coherence tomography (OCT) image analysis. METHODS: Fifty three randomly selected eyes of 53 healthy subjects were recruited for this study. The median age of the participants was 29 years (range: 6 to 67 years). AL was measured for each eye using a Lenstar LS 900 device. OCT imaging of the macula was also performed by Stratus OCT. OCTRIMA software was used to process the raw OCT scans and to determine the weighted mean thickness of 6 intraretinal layers and the total retina. Partial correlation test was performed to assess the correlation between the AL and the thickness values. RESULTS: Total retinal thickness showed moderate negative correlation with AL (r = -0.378, p = 0.0007), while no correlation was observed between the thickness of the retinal nerve fiber layer (RNFL), ganglion cell layer (GCC), retinal pigment epithelium (RPE) and AL. Moderate negative correlation was observed also between the thickness of the ganglion cell layer and inner plexiform layer complex (GCL+IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL) and AL which were more pronounced in the peripheral ring (r = -0.402, p = 0.004; r = -0.429, p = 0.002; r = -0.360, p = 0.01; r = -0.448, p = 0.001). CONCLUSIONS: Our results have shown that the thickness of the nuclear layers and the total retina is correlated with AL. The reason underlying this could be the lateral stretching capability of these layers; however, further research is warranted to prove this theory. Our results suggest that the effect of AL on retinal layers should be taken into account in future studies

    Adaptive parameter selection scheme for nonlinear simulations using field II with operator splitting

    No full text
    Objectives: Understanding and simulating nonlinear pulse propagation is of increasing interest in current ultrasound research. This article gives an adaptive parameter selection scheme for selecting parameters needed when the Field II linear propagation simulator is combined with operator splitting to enable nonlinear propagation simulations.Methods: The general Field II/operator splitting technique was introduced in [1, 2], requiring the selection of various geometrical parameters associated with virtual propagating planes. At that stage these needed to be selected essentially by an iterative trial-and-error technique for a particular transducer geometry, frequency and focussing scheme. Whilst careful parameter selection could provide satisfactory results over a limited propagation range for a given transducer, excitation and focussing scheme, an automated parameter selection method for the general case was still lacking.Results: The paper provides an adaptive method for selecting the required parameters as a function of the varying harmonic and spatial properties of the nonlinear pulse as it propagates through the medium.Conclusions: The method is fully derived and the significant improvement in the simulator’s performance is demonstrated by comparison to previous results in [1, 2]
    corecore